What is full load and no load current?
The terminal voltage when full load current is drawn is called full load voltage (VFL). The no load voltage is the terminal voltage when zero current is drawn from the supply, that is, the open circuit terminal voltage. Some portion of voltage drops down due to internal resistance of voltage source.
Which power is zero at no load in engine?
No load current is motor never be zero in practical case . It is very low with compare to full load current but it is not zero . In ac induction motor no load current is 30-40% of full load current . No load current always supply the magnetizing current component of machine & loss component of machine.
What is the purpose of no load current?
Explanation: No-load current is little bit greater than actual magnetizing current. Total no-load current supplied from the source has two components, one is magnetizing current which is utilized for magnetizing the core and other component is consumed for compensating the core losses in transformer.
What is no load slip?
The speed is assumed to be synchronized. The synchronous speed can be achieved by taking slip = 0 which creates infinite impedance in the rotor branch. Rotor copper loss at no load is very less that its value is negligible. Small current is required to produce adequate torque.
What is the no load speed?
]The no load speed is the RPM at which the DC Motor’s shaft rotate when there is no load attached to it (no torque applied to the output shaft). It is the maximum output speed of the motor.
What are two components of no load current?
No load current of large power transformers consists of active and reactive component. Active component covers hysteresis and eddy current losses in the core. Reactive component (usually called magnetizing current) creates magnetic field / magnetic flux and lags the voltage by 90°.
Why dc series motor is not run at no load?
Thus from equation (2), it is clear that speed of DC Series Motor is inversely proportional to Armature Current Ia. Therefore if the DC Series Motor is started at No Load then the speed of DC Series Motor will become dangerously high which will definitely damage the DC Series Motor.
Are there any parameters that do not include a zero load?
In addition, parameters such as PSRR, line regulation, load regulation, and noise specify a certain load current range that does not include zero, as shown in Figure D. None of this means that a minimum load is required, though. Figure C. ADM7160 output voltage and ground current vs. load current.
What are the specifications for minimum load current?
Figure A. LM1117 minimum load current specifications. Most newer devices are designed to operate with no load, and exceptions to this rule are very limited. The same design techniques that allow LDOs to be stable with any output capacitor, especially low ESR caps, are used to guarantee stability at no load.
What is the definition of a zero sequence current?
Zero Sequence Current. Definition: The unbalanced current flows in the circuit during the earth fault is known as the zero sequence current or the DC component of the fault current.The zero phase sequence means the magnitude of three phases has zero phase displacement.The three vector lines represent the zero sequence current
What happens if there is no load on the capacitor?
Without a load, the leakage current would charge the output capacitor until the switch VDS was low enough to reduce the leakage current to a negligible level, raising the no-load output voltage. The data sheet says that a 500 µA minimum load is required, so a dummy load is advisable if the device will operate at high temperature.