Thermocouple Types

Thermocouple Type Useful/General Application Range
C* 1650-2315°C (3000-4200°F)
E** 95-900°C (200-1650°F)
J 95-760°C (200-1400°F)
K** 95-1260°C (200-2300°F)

What type of thermocouple has the maximum limit of temperature?

Type B Thermocouple
Type B Thermocouple (Platinum Rhodium – 30% / Platinum Rhodium – 6%): The Type B thermocouple is used in extremely high temperature applications. It has the highest temperature limit of all of the thermocouples listed above. It maintains a high level of accuracy and stability at very high temperatures.

What is the accuracy of a type K thermocouple?

Table 2 — Popular thermocouple types

Thermocouple type Overall range Typical accuracy*
Type E (Chromel / Constantan) -200 to 900 1.7 °C
Type J (Iron / Constantan) -40 to 760 2.2 °C
Type K (Chromel / Alumel) -200 to 1300 2.2 °C
Type N (Nicrosil / Nisil) -200 to 1300 2.2 °C

What is difference between T and K type thermocouple?

Type K thermocouple is used in furnaces with magnetic materials processed while type T thermocouples are used in atmospheres with inert pressures. Type K vs T (vs B,R,S,N etc) are different thermocouple wire compositions designed for different temperature ranges.

What is the maximum temperature of a type K thermocouple?

The type K is commonly found in nuclear applications because of its relative radiation hardness. Maximum continuous temperature is around 1,100C. Type K Temperature Range: Thermocouple grade wire, –454 to 2,300F (–270 to 1260C)

What should be considered when choosing a thermocouple?

When choosing a thermocouple consideration should be given to both the thermocouple type, insulation and probe construction. All of these will have an effect on the measurable temperature range, accuracy and reliability of the readings. Type K is the ‘general purpose’ thermocouple.

When do you need a thermocouple extension wire?

Any junction of two different metals will cause a junction. If you need to increase the length of the leads from your thermocouple, you must use the correct type of thermocouple extension wire (eg type K for type K thermocouples). Using any other type of wire will introduce a thermocouple junction.

What is the margin of error for thermocouple wire?

Type K Limits Of Error. Thermocouple wire sensitivities and margins of error are considerations when selecting a type. Type K has a higher margin of error than other types of thermocouple wire; manufacturers that choose this type are generally willing to sacrifice accuracy for the wide range of sensitivity.